ESV751N02YMC, Lenze, 1 Hp, 230V, VFD, Nema 4X, Disconnect, 1/3 Phases
ESV751N02YMC, Lenze, VFD Drives,
SMV SERIES SENSORLESS VECTOR , ESV751N02YMC,
- 1HP /
- 240V,
- 1/3PH(i/p) /
- 230V,
- 3PH(o/p) /
- 4.2A(o/p)
- Cont. /
- NEMA4X c/w DISCONNECT
- VFD SMV
- 1/3 Phases
- 1 or 3 phases input
- 3 phases output
World Class Control Modes of Operation
• Sequencer, timing and step functions, Open Loop Flux Vector, Speed or Torque Control with/without Auto Tuning V/Hz (Constant or Variable)
• Base Frequency Adjustable to Motor Specs Enhanced V/Hz with Auto-tuning Acceleration/Deceleration Profiles
• Two Independent Accel Ramps Two Independent Decel Ramps Linear, S-Type
• Auxiliary Ramp(or Coast)-to-Stop Fixed Accel Boost for Improved Starting 500 Hz Output Frequency High Carrier (PWM Sine-Coded) Frequency 4, 6, 8, 10 kHz Universal Logic Assertion (Selectable)
• Positive or Negative Logic Input Digital Reference Available Braking Functions • DC Injection Braking • Optional Dynamic Braking
• Flux Braking w/adjustable Flux Level and Decel Time Speed Commands • Keypad, Potentiometer Jog and 8 Pre-set Speeds
• Floating Point Control Sequencer, 16 Segments
• Voltage: scalable 0 –10 VDC Current: scalable 4 – 20 mA Process Control
• PID Modes: direct and reverse acting PID Sleep Mode w/ adjustable recovery threshold • Analog Output (speed, load, torque, kW)
• Terminal and keypad status• Elapsed Run or Power -On time (hours) Status Outputs
• Programmable form “A” relay output
• Programmable open collector output
• Scalable 0-10 VDC/2-10 VDC analog output 4-20mA w/500 Ohm Total Impedance Environment Ambient Temperature
• -10 to 55°C • Derate 2.5% per °C above 40°C Comprehensive Diagnostic Tools Real Time Monitoring
• 8 Register Fault History
• Software Version
• Drive Network ID
• DC Bus Voltage (V)
• Output Current (%)
• Motor Current (A)
• Motor Torque (%)
• Power (Hp, kW)
• Energy Consumption (kWh)
• Heatsink Temperature (°C)
• 0 – 10 VDC Input (user defined)
• 4 – 20 mA Input (user defined)
• PID Feedback (user defined) Vigilant System Protection Voltage Monitoring • Low and High DC Bus V Protection
• Low Line V Compensation Current Monitoring Motor Overload Protection
• Current Limiting Safeguard
• Ground Fault
• Short Circuit Protection Four Restart Modes
• Three Flying and One Auto
• User Enabled Loss of Follower Management
• Protective fault
• Go to Pre-set speed or Pre-set set-point
• Initiate System notification Over Temperature Protection International Voltages
• +10/-15% Tolerance
• 120/240V, 1Ø
• 200/240V, 1 or 3Ø
• 200/240V, 3Ø
• 400/480V, 3Ø • 480/600V, 3Ø Global Standards
• UL EAC • cUL C-Tick • CE Low Voltage (EN61800-5-1) • CE EMC (EN61800-3) with optional EMC filter • RoHS • EC S