Menu
Panier 0
MTP250MA2F, 75 Hp, 3600 Rpm, 575 Volts,Fr:250M,B3. 3Ph,TEFC, Premium,

MTP250MA2F, 75 Hp, 3600 Rpm, 575 Volts,Fr:250M,B3. 3Ph,TEFC, Premium,

E-Motor Nations

  • $9,538.56


MTP250MA2F, GR3-CI-TF-225MB3-3D,Techtop,

  • 75 Hp,
  • 3600 Rpm,
  • 575 Volts,
  • Frame 250M,
  • 3 Ph,
  • Mounting B3
  • TEFC,
  • Premium, 

STANDARD FEATURES

  • *Removable feet F1, F2, F0 field convertible up to and including 225 frame (standard F0)
  • 1.15 Service Factor with 60Hz operation / 1.0 Service Factor with 50Hz operation
  • 36 Month warranty
  • Conduit Box is 90º rotatable
  • B5/B14 and increase/decrease flanges available
  • Class I, Division II, Groups A, B, C and D compliant
  • IEEE 45 Marine Duty 160M frame and larger
  • Anti-microbial (tropicalization) on stator winding
  • Cast iron fan covers standard 160M frame and larger
  • Regreasable bearings 160M frame and larger
  • Mobil Polyrex EM polyurea grease
  • 1045 Steel shaft
  • Surface finish:
    • 2-part epoxy coating (cast iron models only)
    • Alkyd enamel RAL7024 - Graphite Gray
    • Black oxide surface treatment for increased corrosion resistance (aluminum models only)
  • Stainless steel nameplate
  • Corrosion-resistant hardware
  • Metric threaded cable gland included with motors
  • Ultra high strength, reusable lifting straps included with motors 160M frame and larger

OPERATING PARAMETERS

  • Continuous (S1) duty
  • Ambient temperatures up to 40ºC
  • Installation up to 1000 MASL (3300 ft.)


CONNECTION

  • Up to and Including 132M Frame (IEC standard terminal block):
  • 9-Lead 230V parallel-wye / 460V series-wye connection
  • 6-Lead 575V wye connection
  • 160M Frame and Larger (IEC standard terminal block):
  • 12-Lead 230V parallel-delta / 460V delta connection
  • 6-Lead 460V or 575V single voltage delta connection


INGRESS PROTECTION

The standard degree of enclosure protection is IP55 (increased IP protection is available). Both drive end and non-drive end are fitted with double lip oil seals, including a rubber shaft slinger on the drive end. Terminal box is double gasketed including nipple seals between conduit box and stator body. DE and NDE end bell fitted with sintered brass one-way drain.


INSULATION AND INVERTER RATING

  • Class F Insulation (Impregnation resin, magnet wire and insulation materials are Class H)
  • Designed to Class B temperature rise
  • Vacuum Impregnated
  • Inverter Rated 15:1 Constant Torque, 30:1 Variable Torque (1.0 S.F. on VFD Power).
  • Exceeds NEMA MG 1 Part 31.4.4.2

Sale

Unavailable

Sold Out